Bring the waterproofing specialist in at design stage. Agree how the space will be used (which sets the BS 8102 grade), choose the system, plan where water goes and how pumps are serviced, and make sure the design and guarantee paperwork will satisfy Building Control, warranty providers and future buyers.
Questions to settle first
- What will the room be used for? Living space needs a Grade 3 environment.
- What is the ground like, and how high is the water table?
- Type A, Type C or both, and does the structure include Type B waterproof concrete?
- Where will the sump go, is dual pumping needed, and how will it be serviced?
- Do any parts extend beyond the house, such as lightwells or decks, that need waterproofing too?
Simplified section through a basement wall. Not to scale.
Type A with Type C
Two lines of defence. The barrier holds back most of the water, and the cavity drain manages anything that gets past it.
Best for
- High-value or high-risk basements
- Where BS 8102 asks for combined protection
- Mixed old and new structures
Higher-risk basements often combine two types of protection.
Who should be involved
Your architect, structural engineer, builder and a waterproofing specialist. The specialist designs the system to BS 8102 and takes design responsibility, which Renlon backs with £10m professional indemnity insurance.
Paperwork to ask for
- A written waterproofing design
- Installation records and an inspected handover
- A guarantee: Renlon’s own 10-year guarantee covers qualifying works, subject to agreed terms
- Maintenance instructions for any pumps and drainage
Related service: Basement & Structural Waterproofing